Emulation Probe User's Manual
M30850T2-EPB User’s Manual  4. Hardware Specifications 
REJ10J1005-0200 Rev.2.00 April 1, 2007 
IMPORTANT 
Notes on Using the CPU Clock at Less than 16 MHz: 
  z To use the CPU clock at less than 16 MHz, execute the command shown below in the Script Window after 
starting the emulator debugger M3T-PD308F. 
 [Command] 
 _settimeout ,300 
Once this command is executed, it remains effective the next time you start the emulator debugger M3T-
PD308F. Therefore, you do not need to execute this command again. 
z When you use the CPU clock at less than 1 MHz, contact your local distributor. 
Notes on Address-Match Interrupt: 
  z Do not single-step an address where an address-match interrupt occurs. 
z When using an address-match interrupt, do not select the check box of "Enable the Address Match Interrupt 
Break Function" in the MCU tab of the Init dialog box. When not using an address-match interrupt, select the 
check box. 
z When you use address-match breaks, if a low reset is input during a user program execution, a debug monitor 
program (about 100 cycles) is executed after a reset is released. Take note that it has effects on the user program 
execution time and the result of a trace. 
  Page 85 of 98 