User`s manual

M30850T2-EPB User’s Manual 3. Usage (How to Use the Emulator Debugger)
R20UT0208EJ0300 Rev.3.00 Page 75 of 100
Sep 16, 2010
3. RAM monitor area setting dialog box
4. RAM monitor area setting dialog box when RAM monitor area is changed from 400h to 1 block
5. RAM monitor area setting dialog box
Specifying the start address
You can set the start address of the RAM area to be
monitored.
Specifying the size
You can set the size to be monitored by specifying the
number of blocks from the start address. One block is 256
bytes in size.
Specifying the start address
You can set the start address of the RAM area to be
monitored. To add a RAM monitor area, click the "Add..."
button. The RAM Monitor Area Setting Window will be
displayed.
Changing the RAM monitor display area
You can change the manner in which the RAM monitor area
you have set in the above dialog box is displayed.
- Up : Shows the blocks at the preceding addresses.
- Down : Shows the blocks at the following addresses.
The background colors of the data display and the code
display sections change with the access attribute as
described below.
- Green : Addresses accessed for read
- Red : Addresses accessed for write
- White : Addresses not accessed
The background colors can be changed as necessary.