REJ10J1319-0100 H8/36109 Group FP-100U User System Interface Cable HS36109ECH61H User’s Manual Renesas Microcomputer Development Environment System H8 Family / H8/300H Tiny Series HS36109ECH61HE Rev.1.00 Revision Date: Apr.
Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage.
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this emulator product. • KEEP the user's manual handy for future reference. Do not attempt to use the emulator product until you fully understand its mechanism. Emulator Product: Throughout this document, the term "emulator product" shall be defined as the following products produced only by Renesas Technology Corp. excluding all subsidiary products.
LIMITED WARRANTY Renesas warrants its emulator products to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas, at its option, will replace any emulator products returned intact to the factory, transportation charges prepaid, which Renesas, upon inspection, shall determine to be defective in material and/or workmanship. The foregoing shall constitute the sole remedy for any breach of Renesas’ warranty.
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state.
SAFETY PAGE READ FIRST • READ this user's manual before using this emulator product. • KEEP the user's manual handy for future reference. Do not attempt to use the emulator product until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the host computer and user system before connecting or disconnecting any CABLES or PARTS. 3.
Warnings on Emulator Usage Be sure to read and understand the warnings below before using this emulator. Note that these are the main warnings, not the complete list. WARNING Always switch OFF the host computer and user system before connecting or disconnecting any CABLES or PARTS. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
Preface Thank you for purchasing this user system interface cable (HS36109ECH61H) for the Renesas’ original microcomputer H8/36109 group. The HS36109ECH61H is a user system interface cable that connects an H8/36109 group E6000 emulator (HS3664EPI61H or HS3664EPI62H; hereinafter referred to as the emulator) to the IC socket for an FP-100U package for the H8/36109 group MCU on the user system and to the H8/36109 group expansion I/O board (HS36109EIO61H).
Contents Preface .........................................................................................................i Section 1 Configuration.....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 2.2 2.3 2.4 2.5 Connecting User System Interface Cable to Expansion I/O Board ..................................
Section 1 Configuration CAUTION Use an NQPACK100SD-ND socket (manufactured by Tokyo Eletech Corporation) for the FP-100U package IC socket on the user system. Figure 1 shows the configuration of the HS36109ECH61H user system interface cable for the FP-100U package.
Table 1 lists the HS36109ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS36109ECH61H Components No.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Expansion I/O Board WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system, the emulator product, and the expansion I/O board or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part.
Expansion I/O board 00 TO ULA EM E 6 0 0 E60 0 2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the expansion I/O board socket (written as USER INTERFACE CABLE), and fasten the expansion I/O board with two CTS screws (M3 x 6 mm).
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
2.2.4 Fastening Cable Head CAUTION 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder. 3.
Fasten the user system interface cable head to the IC socket for an FP-100U package on the user system with the four screws (M2 x 10 mm) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Removing Cable body Push two remove jigs.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-100U package (NQPACK100SD-ND: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad. 17.00 (min.) 13.00 (max.) 17.00 (min.) 13.00 (max.) 0.50 × 24 = 12.00 ± 0.1 0.50 × 24 = 12.00 ± 0.1 0.50 ± 0.05 0.25 ± 0.
2.4 Dimensions for User System Interface Cable Head 76.2 23.0 The dimensions for the user system interface cable head are shown in figure 6. 26.6 23.0 21.5 66.0 Unit: mm Tolerance: ±0.
2.5 Resulting Dimensions after Connecting User System Interface Cable 29.2 The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. 13.3 Cable head User system IC socket (NQPACK100SD-ND manufactured by Tokyo Eletech Corporation) Unit: mm Tolerance: ±0.
12
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Screws (M2 x 6 mm) Socket cover MCU Pin 1 User system IC socket (NQPACK100SD-ND manufactured by Tokyo Eleteck Corporation) Figure 8 Installing MCU to User System 14
Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8/3664 E6000 Emulator User’s Manual (HS3664EPI61HE-U2 or HS3664EPI62HE-U2). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin 1. 3.
Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input specifications. R1 1 MΩ R7 10 k Ω R5 3.3 MΩ HCU04 HCU04 OSC1 To E6000 emulator R2 270 Ω OSC2 System clock oscillator R8 2.
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifically designed for the HS3664EPI61H or HS3664EPI62H emulator. Do not use this cable with any other emulator station. 4.
H8/36109 Group FP-100U User System Interface Cable HS36109ECH61H User's Manual Publication Date: Rev.1.00, April 6, 2006 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Customer Support Department Global Strategic Communication Div. Renesas Solutions Corp. © 2006. Renesas Technology Corp. All rights reserved. Printed in Japan.
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan RENESAS SALES OFFICES http://www.renesas.com Refer to "http://www.renesas.com/en/network" for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.S.A Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501 Renesas Technology Europe Limited Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.
H8/36109 Group FP-100U User System Interface Cable HS36109ECH61H User’s Manual