Section 12 Timer W 
    Rev. 6.00 Mar. 24, 2006 Page 183 of 412 
   REJ09B0142-0600 
12.5.3 Input Capture Timing 
Input capture on the rising edge, falling edge, or both edges can be selected through settings in 
TIOR0 and TIOR1. Figure 12.17 shows the timing when the falling edge is selected. The pulse 
width of the input capture signal must be at least two system clock (φ) cycles; shorter pulses will 
not be detected correctly. 
TCNT
Input capture 
input
φ
N–1 N N+1 N+2
N
GRA to GRD
Input capture
signal
Figure 12.17 Input Capture Input Signal Timing 
12.5.4 Timing of Counter Clearing by Compare Match 
Figure 12.18 shows the timing when the counter is cleared by compare match A. When the GRA 
value is N, the counter counts from 0 to N, and its cycle is N + 1. 
TCNT
Compare 
match signal
φ
GRA
N
N H'0000
Figure 12.18 Timing of Counter Clearing by Compare Match 