Datasheet
Section 13 Serial Communication Interface 3 (SCI3) 
Rev.4.00 Nov. 02, 2005 Page 182 of 304 
REJ09B0143-0400   
Table 13.5 shows the states of the SSR status flags and receive data handling when a receive error 
is detected. If a receive error is detected, the RDRF flag retains its state before receiving data. 
Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the OER, 
FER, PER, and RDRF bits to 0 before resuming reception. Figure 13.8 shows a sample flowchart 
for serial data reception. 
Table 13.5  SSR Status Flags and Receive Data Handling 
SSR Status Flag 
RDRF*  OER  FER  PER  Receive Data  Receive Error Type 
1 1 0 0 Lost  Overrun error 
0 0 1 0 Transferred to RDR Framing error 
0 0 0 1 Transferred to RDR Parity error 
1 1 1 0 Lost  Overrun error + framing error 
1 1 0 1 Lost  Overrun error + parity error 
0 0 1 1 Transferred to RDR Framing error + parity error 
1 1 1 1 Lost  Overrun error + framing error + 
parity error 
Note:  *  The RDRF flag retains the state it had before data reception. 