Datasheet

Section 13 Timer Z
Rev.5.00 Nov. 02, 2005 Page 201 of 500
REJ09B0027-0500
H'0000
Time
Counter cleared by GR compare match
STR
GR value
TCNT value
IMF
Figure 13.9 Periodic Counter Operation
2. TCNT count timing
A. Internal clock operation
A system clock (φ) or three types of clocks (φ/2, φ/4, or φ/8) that divides the system clock
can be selected by bits TPSC2 to TPSC0 in TCR.
Figure 13.10 illustrates this timing.
TCNT
TCNT input
Internal clock
N-1 N N+1
φ
Figure 13.10 Count Timing at Internal Clock Operation