18.4.3 Input Sampling and A/D Conversion Time
The A/D converter has a built-in sample-and-hold circuit. The A/D converter samples the analog
input when the A/D conversion start delay time (t
D
) has passed after the ADST bit is set to 1, then
starts conversion. Figure 18.2 shows the A/D conversion timing. Table 18.3 shows the A/D
conversion time.
As indicated in figure 18.2, the A/D conversion time includes t
D
and the input sampling time. The
length of t
D
varies depending on the timing of the write access to ADCSR. The total conversion
time therefore varies within the ranges indicated in table 18.3.
In scan mode, the values given in table 18.3 apply to the first conversion time. In the second and
subsequent conversions, the conversion time is 128 states (fixed) when CKS = 0 and 66 states
(fixed) when CKS = 1.
(1)
(2)
t
D
t
SPL
t
CONV
φ
Address
Write signal
Input sampling
timing
ADF
[Legend]
(1) :
(2) :
t
D
:
t
SPL
:
t
CONV
:
ADCSR write cycle
ADCSR address
A/D conversion start delay time
Input sampling time
A/D conversion time
Figure 18.2 A/D Conversion Timing