Section 13 Timer Z
Rev.5.00 Nov. 02, 2005 Page 203 of 500
REJ09B0027-0500
13.4.2 Waveform Output by Compare Match
Timer Z can perform 0, 1, or toggle output from the corresponding FTIOA, FTIOB, FTIOC, or
FTIOD output pin using compare match A, B, C, or D.
Figure 13.12 shows an example of the setting procedure for waveform output by compare match.
[1] Select 0 output, 1 output, or toggle
output as a compare much output, by
means of TIOR. The initial values set in
TOCR are output unit the first compare
match occurs.
[2] Set the timing for compare match
generation in GRA/GRB/GRC/GRD.
[3] Enable or disable the timer output by
TOER.
[4] Set the STR bit in TSTR to 1 to start the
TCNT count operation.
[1]
Output selection
Select waveform output mode
[2]
Set output timing
[3]
Enable waveform output
[4]
Start count operation
<Waveform output>