Datasheet
Section 14 Serial Communication Interface 3 (SCI3) 
    Rev.5.00 Nov. 02, 2005 Page 223 of 418 
   REJ09B0028-0500 
No
<End>
Yes
Start transmission
Read TDRE flag in SSR[1]
Set MPBT bit in SSR
Yes
No
No
Yes
Read TEND flag in SSR
[2]
No
Yes
[3]
Clear PDR to 0 and set PCR to 1
Clear TE bit in SCR3 to 0
TDRE = 1
All data transmitted?
TEND = 1
Break output?
Write transmit data to TDR
[1]  Read SSR and check that the TDRE 
flag is set to 1, set the MPBT bit in 
SSR to 0 or 1, then write transmit 
data to TDR. When data is written to 
TDR, the TDRE flag is automatically 
cleared to 0.
[2]  To continue serial transmission, be 
sure to read 1 from the TDRE flag to 
confirm that writing is possible, then 
write data to TDR. When data is 
written to TDR, the TDRE flag is 
automatically cleared to 0.
[3]  To output a break in serial 
transmission, set the port PCR to 1, 
clear PDR to 0, then clear the TE bit 
in SCR3 to 0.
Figure 14.16 Sample Multiprocessor Serial Transmission Flowchart 