Datasheet

Section 9 Timers
Rev. 8.00 Mar. 09, 2010 Page 295 of 658
REJ09B0042-0800
TCG Clear Timing
TCG can be cleared by the rising edge, falling edge, or both edges of the input capture input
signal.
Figure 9.14 shows the timing for clearing by both edges.
Input capture
input signal
Input capture
signal F
Input capture
signal R
TCGN NH'00 H'00
Figure 9.14 TCG Clear Timing