Analog Switch Data Sheet

HD74HC1G66
Rev.8.00, Jan.27.2004, page 4 of 8
Electrical Characteristics
Ta = 25°C Ta = –40 to 85°C
Item Symbo
V
CC
(V)
Min Typ Max Min Max
Unit Test Conditions
2.0 1.5 1.5
4.5 3.15 3.15
V
IH
6.0 4.2 4.2
2.0 0.5 0.5
4.5 1.35 1.35
Input voltage
V
IL
6.0 1.8 1.8
V Control input only
2.0 200 450 550
4.5 90 160 180
On resistance R
ON
6.0 80 130 140
V
C
= V
IH
V
IN
= V
CC
or GND
I
T
= 1 mA
2.0 600 1500 2000
4.5 125 200 250
Peak on
resistance
R
ON
(p)
6.0 100 170 210
V
C
= V
IH
V
IN
= 0 to V
CC
I
IN/OUT
= 1 mA
I
S
(off) 6.0 ±0.1 ±1.0 µAV
C
= V
IL
V
IN
= V
CC
, V
OUT
= GND
or V
IN
= GND,
V
OUT
= V
CC
Leak current
I
S
(on) 6.0 ±0.1 ±1.0 µAV
C
= V
IH
V
IN
= V
CC
or GND
Input current I
IN
6.0 ±0.1 ±1.0 µAV
IN
= V
CC
or GND
Operating
current
I
CC
6.0 1.0 10.0 µAV
IN
= V
CC
or GND