Rev. 1.00, 05/04, page 404 of 544
Figure 15.5 shows the timing of the LPCPD and LRESET signals.
LPCPD
LRESET
LAD3–LAD0
LFRAME
LCLK
At least 30 µs
At least 100 µs
At least 60 µs
Figure 15.5 Power-Down State Termination Timing