Datasheet

Section 14 CRC Operation Circuit (CRC)
Rev. 2.00 Sep. 28, 2009 Page 403 of 870
REJ09B0429-0200
14.4 Note on CRC Operation Circuit
Note that the sequence to transmit the CRC code differs between LSB-first transmission and
MSB-first transmission.
CRCDIR
CRCDORH
CRCDORL
1. CRC code generation
2. Transmission data
(i) LSB-first transmission
CRC code generation
After specifying the operation method, write data to CRCDIR in the sequence of (1) (2) (3) (4).
CRC code
Output
7
770 0
0
0
70
00 0777
7
(1) (2) (3) (4)
(5)
(6)
(1)(2)(3)(4)
(6)
(5)
(ii) MSB-first transmission
CRC code
Output
77000000777
7
(6)(5)(4)(3)
(2)
(1)
Figure 14.6 LSB-First and MSB-First Transmit Data