Figure 19.9 shows the timing of the LPCPD and LRESET signals.
LPCPD
LRESET
LAD3 to LAD0
LFRAME
LCLK
At least 30 µs
At least 100 µs
At least 60 µs
Figure 19.9 Power-Down State Termination Timing