Datasheet
RL78/L12    CHAPTER 12 SERIAL ARRAY UNIT 
R01UH0330EJ0200 Rev.2.00      445 
Dec 13, 2013 
Figure 12-50. Procedure for Resuming Slave Transmission 
Starting setting for resumption
Port manipulation 
Changing setting of the SPSm register
Changing setting of the SMRmn register
Changing setting of the SOm register
Port manipulation 
Writing to the SSm register
Disable data output of the target channel 
by setting a port register and a port 
mode register. 
Re-set the register to change the operation 
clock setting. 
Re-set the register to change the transfer baud 
rate setting (setting the transfer clock by dividing 
the operation clock (f
MCK
)).
Re-set the register to change serial 
mode register mn (SMRmn) setting. 
Set the initial output level of the serial 
data 
(
SOmn
)
.
Enable data output of the target channel 
by setting a port register and a port mode 
register. 
Set the SSmn bit of the target channel to 1 
(SEmn = 1 : to enable operation). 
Sets transmit data to the SIOp register (bits 
7 to 0 of the SDRmn register) and wait for a 
clock from the master. 
(Selective)
(Selective)
Changing setting of the SDRmn register
(Selective)
(Selective)
(Essential)
(
Essential
)
(Essential)
(Essential)
Re-set the register to change serial 
communication operation setting register 
mn (SCRmn) setting. 
(Selective)
Changing setting of the SCRmn register
If the OVF flag remain set, clear this 
using serial flag clear trigger register mn 
(SIRmn). 
(Selective)
Clearing error flag 
Set the SOEmn bit to 1 and enable 
output from the target channel. 
(Essential)
Changing setting of the SOEm register
Completing resumption setting
Starting communication 
Set the SOEmn bit to 0 to stop output 
from the target channel. 
(Selective)
Changing setting of the SOEm register
(Essential)
Ye s 
No 
Wait until stop the communication target 
(master) 
Completing master 
p
re
p
arations?
Remark If PER0 is rewritten while stopping the master transmission and the clock supply is stopped, wait 
until the 
transmission target (master) stops or transmission finishes, and then perform 
initialization instead of restarting the transmission. 
<R> 