Datasheet

R8C/18 Group, R8C/19 Group 5. Electrical Characteristics
Rev.1.40 Apr 14, 2006 Page 26 of 38
REJ03B0124-0140
NOTES:
1. The measurement condition is V
CC = 2.7 V to 5.5 V and Topr = -40°C to 85 °C.
2. Necessary time until the voltage detection circuit operates when setting to 1 again after setting the VCA26 bit in the VCA2
register to 0.
3. Ensure that V
det2 > Vdet1.
NOTES:
1. The measurement condition is V
CC = 2.7 V to 5.5 V and Topr = -40°C to 85 °C.
2. Time until the voltage monitor 2 interrupt request is generated after the voltage passes V
det1.
3. Necessary time until the voltage detection circuit operates when setting to 1 again after setting the VCA27 bit in the VCA2
register to 0.
4. Ensure that V
det2 > Vdet1.
Table 5.6 Voltage Detection 1 Circuit Electrical Characteristics
Symbol Parameter Condition
Standard
Unit
Min. Typ. Max.
V
det1
Voltage detection level
(3)
2.70 2.85 3.00 V
Voltage detection circuit self power consumption VCA26 = 1, V
CC = 5.0 V 600 nA
t
d(E-A) Waiting time until voltage detection circuit operation
starts
(2)
−−100 µs
Vccmin MCU operating voltage minimum value 2.7 −−V
Table 5.7 Voltage Detection 2 Circuit Electrical Characteristics
Symbol Parameter Condition
Standard
Unit
Min. Typ. Max.
V
det2
Voltage detection level
(4)
3.00 3.30 3.60 V
Voltage monitor 2 interrupt request generation time
(2)
40 −µs
Voltage detection circuit self power consumption VCA27 = 1, V
CC = 5.0 V 600 nA
t
d(E-A) Waiting time until voltage detection circuit operation
starts
(3)
−−100 µs