Datasheet
R01DS0190EJ0100 Rev.1.00 Page 82 of 107
Jun 19, 2013
RX111 Group 5. Electrical Characteristics
Figure 5.38 SCI Input/Output Timing: Clock Synchronous Mode
Figure 5.39 A/D Converter External Trigger Input Timing
Figure 5.40 CLKOUT Output Timing
t
TXD
t
RXS
t
RXH
TXDn
RXDn
SCKn
n = 0, 1, 5, 6, 8, 9
ADTRG0#
PCLK
t
TRGW
t
Cf
t
CH
t
Ccyc
t
Cr
t
CL
CLKOUT pin output
Test conditions: V
OH
= VCC × 0.7, V
OL
= VCC × 0.3, I
OH
= -1.0 mA, I
OL
= 1.0 mA, C = 30 pF