Datasheet
R01DS0190EJ0100 Rev.1.00 Page 52 of 107
Jun 19, 2013
RX111 Group 5. Electrical Characteristics
Table 5.7 DC Characteristics (5)
Conditions: VCC = AVCC0 = VCC_USB = 1.8 to 3.6 V, VSS = AVSS0 = VREFL0 = VSS_USB = 0 V, T
a
= –40 to +105°C
Item Symbol
Typ
*
4
Max Unit
Test
Conditions
Supply
current*
1
High-speed
operating mode
Normal
operating
mode
No peripheral operation*
2
ICLK = 32 MHz
I
CC
3.2 — mA
ICLK = 16 MHz
2.2 —
ICLK = 8 MHz
1.7 —
All peripheral operation:
Normal*
3
ICLK = 32 MHz
10.6 —
ICLK = 16 MHz
6.1 —
ICLK = 8 MHz
3.7 —
All peripheral operation:
Max.*
3
ICLK = 32 MHz
—24
Sleep mode No peripheral operation*
2
ICLK = 32 MHz
1.8 —
ICLK = 16 MHz
1.4 —
ICLK = 8 MHz
1.1 —
All peripheral operation:
Normal*
3
ICLK = 32 MHz
6.4 —
ICLK = 16 MHz
3.7 —
ICLK = 8 MHz
2.4 —
Deep sleep
mode
No peripheral operation*
2
ICLK = 32 MHz
1.2 —
ICLK = 16 MHz
1.0 —
ICLK = 8 MHz
0.90 —
All peripheral operation:
Normal*
3
ICLK = 32 MHz
4.6 —
ICLK = 16 MHz
2.8 —
ICLK = 8 MHz
1.8 —
Increase during BGO operation*
5
2.5 —
Middle-speed
operating modes
Normal
operating
mode
No peripheral operation*
6
ICLK = 12 MHz
I
CC
2.0 — mA
ICLK = 8 MHz
1.3 —
ICLK = 1 MHz
0.75 —
All peripheral operation:
Normal*
7
ICLK = 12 MHz
4.9 —
ICLK = 8 MHz
3.5 —
ICLK = 1 MHz
1.2 —
All peripheral
operation: Max.*
7
ICLK = 12 MHz
—11
Sleep mode No peripheral operation*
6
ICLK = 12 MHz
1.4 —
ICLK = 8 MHz
0.85 —
ICLK = 1 MHz
0.65 —
All peripheral operation:
Normal*
7
ICLK = 12 MHz
3.2 —
ICLK = 8 MHz
2.2 —
ICLK = 1 MHz
1.0 —
Deep sleep
mode
No peripheral operation*
6
ICLK = 12 MHz
1.2 —
ICLK = 8 MHz
0.70 —
ICLK = 1 MHz
0.60 —
All peripheral operation:
Normal*
7
ICLK = 12 MHz
2.5 —
ICLK = 8 MHz
1.8 —
ICLK = 1 MHz
0.90 —
Increase during BGO operation*
5
2.5 —