User`s manual
Section 2 Software Specifications when Using the SH7147 Group Debugging MCU Board
Rev. 1.00 Apr. 04, 2008 Page 26 of 30
REJ10J1828-0100
2.2.7 Performance Measurement Function
The emulator supports the performance measurement function.
1. Setting the performance measurement conditions
To set the performance measurement conditions, use the [Performance Analysis] dialog box
and the PERFORMANCE_SET command. When any line in the [Performance Analysis]
window is clicked with the right mouse button, a popup menu is displayed and the
[Performance Analysis] dialog box can be displayed by selecting [Setting].
Note: For the command line syntax, refer to the online help.
(a) Specifying the measurement start/end conditions
The measurement start/end conditions are specified by using Event Condition 1,2. The
[Ch1,2,3] list box of the [Combination action (Sequential PtoP)] dialog box can be used.
Table 2.14 Measurement Period
Classification Item Description
Selection in
the [Ch1, 2, 3]
list box
Ch2 to Ch1
PA
The period from the satisfaction of the condition set in Event
Condition 2 (start condition) to the satisfaction of the condition set
in Event Condition 1 (end condition) is set as the performance
measurement period.
Ch1 to Ch2
PA
The period from the satisfaction of the condition set in Event
Condition 1 (start condition) to the satisfaction of the condition set
in Event Condition 2 (end condition) is set as the performance
measurement period.
Other than
above
The period from the start of execution of the user program to the
occurrence of a break is measured.