H Manual

11
2.6 Resulting Dimensions after Connecting User System Interface Board
The resulting dimensions, after connecting the user system interface board to the user system, are
shown in figure 7.
Unit: mm
Tolerance: ±1.0 mm
35.6
16.0
57.6
User system
EV-chip board
IC socket
(IC149-120-043-B51
manufactured by
YAMAICHI ELECTRONICS Co., Ltd.)
56.5
56.5
45.0
45.0
SPACER (φ5.8)
Figure 7 Resulting Dimensions after Connecting User System Interface Board