6. Motor Calibration using the PC GUI Interface
A full calibration of the motor can be performed via the PC User Interface.
The most important parameters to test are the following:
1. Stator resistance
2. Start-up current
3. Maximum current
4. Synchronous inductance
5. Current PI parameters
6. Speed PI parameters
Warning:
Do not try to start the motor before entering the initial calibration parameters otherwise the system could be damaged.
6.1. Stator Phase Resistance
The Phase resistance can be found by measuring the phase-to-phase resistance using a meter.
The measured value should be divided by 2.
Please enter the value in the parameter 08, “Stator Resistance” as shown below.
Click the button “Write” to save the new parameter value.
Since the measurement unit is Ohm/10, the value 23 of the picture means 2.3 Ohm.