Error states
System Status
Graphic display
Details
Probe Start
Low
battery/
credit
Probe
status
Error Signal
Tool
Setter
New Part Setter
acquisition
required
If the Part Setter spin/m-
code sip switch is changed
after it is acquired, the part
Setter will need to be re-
acquired or the switch must
be changed back
3D Tool setter
on, attempted
switch on of
Part Setter
The part Setter LED will flash
to indicate a multiple
equipment error, the LED
will continue to flash while
conditions exist
Attempted
switch on of
both pieces of
equipment
simultaneously
The Part Setter and 3D Tool
Setter LEDs with flash to
show a multiple equipment
error
System over
current
Flash the low credit/battery,
status and error LEDs. The
error will continue until the
fault is cleared and the
power is cycled
Hardware
validation
failure
Part Setter on,
seated with low
battery and
credit
The low credit/battery LED
will flash Red and Yellow
while conditions persist
Part Setter on
and triggered
Part Setter on,
seated with
poor signal
The signal LED is graded
from Green to Amber to
show the Part Setter signal
strength. 100% indicates
best signal
Part Setter
triggered start