User Manual

Primo Radio Part Setter
Symptom Cause Action
Part Setter fails to
power up (no LEDs
illuminated or fails to
indicate current Part
Setter settings)
No credit token
Insert credit token
Dead battery Change battery
Wrong battery Change battery
Battery inserted incorrectly
Check battery insertion/polarity.
Battery not removed for long enough
so the Part Setter has not reset
Remove battery for a minimum of 5
seconds
Part Setter fails to
switch on
Dead battery Change battery
Battery inserted incorrectly Check battery insertion/polarity
Part Setter out of range Check position of Interface
No Interface ‘start/stop’ signal (radio-
on mode only)
Check Interface for green start LED
Incorrect spin speed (spin-on mode
only)
Check spin speed and duration
Incorrect switch-on method configured Check configuration and alter as required
Primo in hibernation mode (radio-on
mode only)
Ensure probe is in range and wait up to
30 seconds, then resend switch-on signal.
Check position of Interface
System credit depleted
Insert new credit token
Machine stops
unexpectedly during a
cycle
Radio link failure/Part Setter out of
range.
Check Interface/receiver and remove
obstruction
Interface receiver/machine fault Refer to receiver/machine user’s guide
Dead battery Change battery
Part Setter unable to find target
surface
Check that part is correctly positioned
and that stylus has not broken
Stylus not given sufficient time to
settle from a rapid deceleration
Add a short dwell before the move
(length of dwell will depend on stylus
length and rate of deceleration). Max
dwell is one second
Part Setter crashes Work piece obstructing Part Setter
path
Review software
Part Setter length offset missing Review software
Poor repeatability
and/or accuracy
Debris on part or stylus Clean part and stylus
Poor tool change repeatability Redatum after each tool change
Loose Part Setter mounting on shank
or loose stylus
Check and tighten as appropriate
Calibration out of date and/or
incorrect offsets
Review probing software
Fault finding
7.1
Primo installation guide
Fault
finding
7.1