User's Manual

2.3
RLP40 basics
RLP40 switch on method
Switch on options are configurable
RLP40 switch off method
Switch off options are configurable
Switch on time
Radio on
Radio switch on is commanded by
machine input.
Radio off
Radio switch off is commanded by
machine input. A timer automatically
switches the probe off 90 minutes
after the last trigger if it is not turned
off by machine input.
Timer off (timeout)
Timeout will occur 12, 33 or 134
seconds (user configurable) after the
last probe trigger or reseat.
1 second maximum
Note: This assumes
a good radio
communication link.
In a poor RF
environment this may
rise to a maximum of
3 seconds.
Spin on
Spin at 500 rev/min for 1 second
minimum (6 seconds maximum).
Spin off
Spin at 500 rev/min for 1 second
minimum (6 seconds maximum).
A timer automatically switches the
probe off 90 minutes after the last
trigger if it is not spun.
Timer off (timeout)
Timeout will occur 12, 33 or 134
seconds (user configurable) after the
last probe trigger or reseat.
2 seconds maximum.
Note: The 2 seconds
starts from the
moment the spindle
reaches 500 rev/min.
NOTE: After being switched on, the RLP40 must be on for 1 second minimum (the RLP40 must be
spun down before it can be spun off again) before being switched off.