User's Manual

2.7
RLP40 basics
Typical battery life
Battery type Spin switch on Radio switch on Continuous use
Standby life
5% usage
(72 minutes/day)
Standby life
5% usage
(72 minutes/day)
Lithium Thionyl
Chloride
240 days 150 days 290 days 170 days 450 hours
Environment
(As defined in
BS EN 61010 - 1:2001)
IP rating IPX8 (BS5490, IEC 60529) 1 atmosphere
Storage temperature
-10 °C to 70 °C (14 °F to 158 °F)
Operating temperature 5 °C to 50 °C (41 °F to 122 °F)
Altitude Exceeds 2000 m
Pollution degree 3
Relative humidity No humidity restriction
Indoor use only
Battery types
2 x 1/2 AA (3.6V) Lithium Thionyl Chloride
Battery reserve life
Approximately one week after a low battery warning is first given
Low battery indication
Blue flashing LED in conjunction with normal red or green probe status
LED
Dead battery indication
Constant or flashing red