User's Manual

4.5
Trigger Logic™
NOTE: To partner an RLP40 with an RMI please
see "RLP40 – RMI partnership". Once acquisition
has been successful, the RLP40 will revert to
‘Acquisition mode off’.
NOTE: Further probes used
require the same multiple probe
mode setting, but do not need to be
partnered with the RMI.
Cease triggering here, unless the multiple probe mode is required
in which case deflect stylus > 4 seconds
NOTE: If no changes are made in multiple probe mode, then deflecting the stylus for more
than 4 seconds will return the probe settings to ‘To change switch-on method’
NOTE: To partner a
RLP40 with a RMI,
please see RLP40 - RMI
partnership.
Acquisition mode
off
Acquisition mode
Multiple probe mode (omitted for radio-on)
(See ‘Multiple probe mode settings’ to view all 16 choices)
Mode off Mode on
Return to “Change switch-on method”
Acquisition mode
on
Machine 1
Machine 2
Machine 16
Acquisition mode
off
Acquisition mode
Acquisition mode
on
New settings
complete