User's Manual

RLP40 installation guide
5.4
Maintenance
RLP40 eyelid
The RLP40 is fitted with a metal eyelid that
protects the internal components of the probe
from hot chip and coolant environment. Dirt may
accumulate in the cavity underneath the metal
eyelid seal.
To remove this dirt, once a month, remove the
front cap (using a coin or flat blade screwdriver)
and then remove all of the residue with a low-
pressure jet of coolant.
A
1
3
2
4
Do not use a sharp tool or a degreasing agent.
The cleaning interval may be extended or
reduced, depending on the rate dirt accumulates.
If the inner diaphragm is damaged, return the
probe to your supplier for repair.
Re-assembling the probe
DO NOT use the probe with the cap removed.
Check that the probe is firmly secured in its
mounting.
Apply coin or flat
blade screwdriver
to both sides to
sequentially lever
front cap from probe
body