User's Manual

6.1
Symptom Cause Action
Probe fails to power up
(no LEDs illuminated or
fails to indicate current
probe settings).
Dead batteries. Change batteries.
Wrong batteries. Change batteries.
Batteries inserted incorrectly. Check battery insertion/polarity.
Batteries removed for too short a
time and probe has not reset.
Remove batteries for a minimum
of 5 seconds.
Probe fails to switch on.
Dead batteries. Change batteries.
Batteries inserted incorrectly. Check battery insertion/polarity.
Probe out of range. Check position of RMI, see
operating envelope.
No RMI 'start/stop' signal (radio
on mode only).
Check RMI for green start LED.
Incorrect spin speed (spin switch
on only).
Check spin speed and duration.
Incorrect switch on method
configured.
Check configuration and alter as
required.
Incorrect multiple probe mode
setting configured.
Check configuration and alter as
required.
RLP40 in hibernation mode
(radio on mode only).
Ensure probe is in range and wait
up to 30 seconds, then resend
switch on signal.
Check position of RMI, see
operating envelope.
Fault finding