6.4
Fault finding
Symptom Cause Action
RMI error LED lit during
probing cycle.
Probe not switched on or probe
timed out.
Change setting. Review turn off
method.
Probe out of range. Check position of RMI, see
operating envelope.
RMI low battery LED lit.
Low batteries. Change batteries soon.
Reduced range.
Local radio interference. Identify and remove.
Probe fails to switch off.
Incorrect switch off method
configured.
Check configuration and alter as
required.
No RMI 'start/stop' signal (radio
on mode only).
Check RMI for green start LED.
Probe in timeout mode and
placed in tool magazine and is
being triggered by movement.
Use shorter timeout setting or use
different switch off mode.
Incorrect spin speed (spin turn on
only).
Check spin speed.
Probe goes into Trigger
Logic™ configuration
mode and cannot be
reset.
Probe was triggered when
batteries were inserted.
Do not touch the stylus or stylus
mounting face during battery
insertion.