User's Manual

21RMI cable sealing and fitting flexible conduit
Cable
Adaptor A
Conduit
termination
piece
Plastic
olive
Nut B
Conduit bulkhead fittings require a
clearance hole for an M16 thread
CAUTION:
Failure to adequately protect the cable
can result in system failure due to
either cable damage or coolant ingress
through cores into the RMI.
Failure due to inadequate cable
protection will invalidate the warranty.
When tightening or loosening nut B
onto conduit ensure that torque is only
applied between A and B.
Coolant and dirt are prevented from entering
the RMI by the cable sealing gland. The cable
can be protected against physical damage by
fitting flexible conduit if required.
Recommended flexible conduit is Anamet
TM
Sealtite HFX (5/16 in) polyurethane.
A conduit kit is available - see Parts list.
RMI cable sealing
Fitting flexible conduit
1. Slide nut B and plastic olive onto conduit.
2. Screw conduit termination piece into end of
conduit.
3. Fit conduit to adaptor A and tighten nut B.
!
Flexible
conduit