User's Manual

24
Side exit to rear exit cable conversion
1. Remove RMI cover (page 22).
2. Remove 3 crosshead screws retaining
PCB. Carefully remove PCB and
disconnect cable connection to PCB.
3. Unscrew cable clamp (2 x crosshead
screws).
4. Unscrew conduit gland from RMI body.
5. Unscrew rear exit plug and rubber
grommet from RMI body.
6. Carefully remove cable assembly and refit
through rear exit hole. Tighten conduit gland.
7. Fit rubber grommet and rear exit plug to side
exit hole and tighten.
8. Fit cable assembly using cable clamp at
3 o’clock position.
9. Connect PCB to cable connector. Insert
PCB and retain with 3 cross head screws.
10. Fit the RMI cover (page 22).
Side exit to rear exit cable conversion
CAUTION
Conversion from side exit cable
to rear exit cable must only be
undertaken by qualified personnel.
Failure to do so will invalidate the
warranty.
!