OM16 OPTICAL MODULE
dimensions mm (in)
137.5mm (5.41in)
112.5mm (4.43in)
M32x1.5
Ø29mm
(1.14in)
38.3mm (1.51in)
86mm (3.39in)
60mm (2.36in)
51mm (2.01in)
32.5mm (1.28in)
17.5mm (0.69in)
10mm (0.39in)
50mm (1.97in)
25mm
(0.98in)
Ø10.5mm
(0.04in)
WIRING CONNECTIONS
The OM16 is connected to the MI16 Interface with 25 metres
of cable. The cable uses four conductors and the screen.
These should be connected as below:
Cable screen
Connect to ground (MI16 pin 4 - see page 19).
Red and Yellow
Connect both to the +ve OM16 pin on the MI16 Interface
(MI16 pin 5 - see page 19).
Blue and Green
Connect both to the -ve OM16 pin on the MI16 Interface
(MI16 pin 6 - see page 19).
SEALING
The OM16 is sealed to IP68.
A gland suitable for sealing to flexible conduit is supplied as stan-
dard.
The OM16 cable should be protected by flexible conduit.
The recommended type is Thomas and Betts SHURESEAL 1/4in,