User's Manual

13
Probe settings
Radio on
Radio switch on when
commanded by an M code.
Spin on
Spin at 650 rev/min for
1 second minimum (6 seconds
maximum).
Shank switch on
Radio off
Radio switch off when commanded by an M code.
A timer automatically switches the probe off after 90 minutes
from the last trigger if not turned off by an M code.
Timer off (time out)
Time out will occur (12, 33 or 134 seconds) after the last probe
trigger or reseat.
Spin off
Spin at 650 rev/min for 1 second minimum (6 seconds
maximum).
A timer automatically switches the probe off after 90 minutes
from the last trigger if not spun.
Timer off (time out)
Time out will occur (12, 33 or 134 seconds) after the last probe
trigger or reseat.
Shank switch off