User's Manual

22
System setup is achieved using trigger logic and
powering on the RMI.
Trigger logic is a method that allows user
configuration of the options available in the
RMP60. Trigger logic uses a sequence of
RMP60 triggering and battery insertion followed
by further RMP60 triggering.
This leads the user through a series of choices,
allowing selection of the required options.
Reviewing of choices can be made by battery
insertion alone. See Reviewing probe settings.
To partner an RMP60 and RMI
Partnering is only required during initial system
set-up. Further partnering is only required if
either the RMP60 or RMI is changed.
Partnering will not be lost by reconfiguration
of probe settings or when changing batteries.
Partnering can take place anywhere within the
operating envelope.
RMP60-RMI partnership
RMP60-RMI partnership
1. Use trigger logic to access the RMP60
configuration mode.
2. Configure the turn on method (if not
configured).
3. Configure the turn off method (if not
configured).
4. Enter the acquisition mode by deflecting
the stylus.
5. Remain in ‘Acquisition Mode Off’ by not
releasing the stylus. This allows time to get
the RMI ready for partnering.
6. Power on the RMI.
7. Watch the RMI signal LED; after a couple
of seconds the LED will repeatedly flash on
and off green. This is the start of a 10
second interval in which the RMI is in
acquisition mode.
continued on next page