Fault-finding
RMP60 fails to switch off.
RMP60 status LEDs
continuous red.
Poor battery life.
Incorrect switch off method
configured.
No RMI ‘start/stop’ signal
(radio on mode only)
Probe in time out mode and
placed in tool magazine and is
being triggered by movement.
Malfunctioning shank switch
(shank switch mode only).
Incorrect spin speed
(spin switch on only).
Dead batteries.
Radio link failure – RMP out
of RMI range.
RMI power has been removed.
Local radio interference.
Check configuration and alter as
required.
Check RMI for green start LED.
Review use of time out mode.
Increase spring force.
Check switch operation.
Check spin speed.
Change batteries.
Check position of RMI,
see Operating envelope.
Check power to RMI, leave
RMI powered all the time.
Identify source and move it
away from the RMP60 and RMI.
Symptom Cause Action