Before you put device into operation
Put the fountain pump into a shallow pond or a similar place and switch on. Through various nose
pieces, the pumped water is sprayed out in different patterns.
For operation, the fountain pump should be submerged in water at 30 - 40 cm depth, so that the
extension tube and a selected nose piece would rise over the water level.
At that, do not put the pump into bottom sludge, but use some slightly raised platform.
Using the T-socket supplied with the device you can attach (if desired) another nose piece or a
hose e.g. for watering the garden.
Never block both shutoff valves of the T-socket, otherwise the fountain pump can be
damaged!
A grip on the top enables to fasten the fountain pump additionally with a rope.
Never hold or fasten the fountain pump by the mains cabel or the hose; only the grip on
the top can be used for this purpose.
The fountain pump can only be operated in the upright position!
The pumped water should be clean and clear. Only fine suspended matter is admissible, which may
occur in every normal garden pond. Otherwise the nose pieces will be occluded!
Coarser impurities (leaves, dirt particles, pebbles etc.) occlude the suction ports; furthermore, they
block the pump.
Getting started
Insert the mains plug of the fountain pump to a mains socket.
The fountain pump starts immediately and begins pumping water.
If the water is not pumped, it can be indicative of air in the pump. Wait for few seconds or remove
and insert the plug briefly from the mains socket for several times.
Removing from service
Should the fountain pump be taken out of service (e.g. for cleaning, maintenance or storage in
winter), then proceed as follows:
Disconnect the fountain pump from the power supply, pull the mains plug out of the mains
socket.
Take the fountain pump out of the water using the carrier handle (or the fastening rope
attached).
Never lift the fountain pump using the hose or the mains cord! Otherwise the power
cord may get damaged, risk of an electric shock!
If a hose is mounted to the fountain pump (e.g. via the T-socket), then disconnect it from the
fountain pump.
Let the residual water drain out of the fountain pump holding it slantwise.
Dry up the fountain pump and the power cord. If required, clean its outer surface and filter. Wind
up the mains cable.
In winter, keep the water pump in a dry space protected against frost.
Also do not forget to empty the hoses laid outdoor to avoid frost damages; open water
taps if available.
Only the carrying handle can be used to carry the fountain pump. Never hold it using the hose or
the mains cord.
A small quantity of water remains in the fountain pump after use or after the emptying operation.
Therefore, when storing or transporting the pump in a vehicle, use an appropriate mat.
Maintenance and cleaning
Before cleaning disconnect the fountain pump from the mains; remove the mains plug from the
power socket.
Use a soft clean cloth to clean the outer surfaces of the fountain pump. If necessary rinse the outer
surface with clear water.
The lower part of the filter can be removed from the fountain pump to facilitate cleaning of the
filter and interior parts of the pump. Only clean running water can be used for this purpose. Turn
the fountain pump upside down. Holding the housing firmly, turn the lower part in an anticlockwise
motion a little to the left (1).
You can also remove the impeller. To do that, remove the single screw (2). At that, before you take
out the impeller, you have to overcome certain resistance due to magnetic force (3).
After cleaning reassamble the fountain pump completely and properly.
Before putting in storage, dry up the fountain pump and the power cord.
Never use abrasive cleaning agents, cleaning alcohol or other chemical solutions,
since these can damage the housing or even impair functionality.
Disposal
Dispose of the unserviceable product according to the relevant statutory regulations!
Technical data
Operating voltage............................... 230 V/AC, 50 Hz
Protection class ................................. I
Protection type ................................... IPX8
Nominal output ................................... 38 W
Connection cable ............................... H05RN-F, 3 x 0,75 mm², length app. 10 m
Delivery lift .......................................... max. 1,9 m above the intake port
Depth of immersion ........................... max. 3 m
Flow rate .............................................. up to 1400 l/h
Temperature of water ........................ max. +35 °C
Hose diameter .................................... 15 mm (1/2”)
Dimensions.......................................... 115 x 190 mm (Ø x H)
............................................................... (max. height with extension tube and spraying nozzle 470 mm)
Weight .................................................. app. 1,9 kg (without extension tube/spraying nozzle)