For example, if the target tolerance is set to "±1%", targets whose capacities are
2.02GB or more and 1.98GB or less will not be copied.
3. Asynchronous Settings [7.Setup >> Asynchronous]
Users can activate Asynchronous copy by selecting “Enable” or deactivating it by
selecting “Disable” For Asynchronous copy to run, the source’s data must be
smaller than the system’s buffer memory and set to “Enable”. However, if set to
“Disable”, regardless of content size, synchronous copy will be performed.
The conditions of executing “Asynchronous Copy”
DISABLE Asynchronous Copy
ENABLE Asynchronous Copy
Data > Buffer
Data < Buffer
Note
The buffer memory may vary depending on product model.
4. Power Off Time Between Copy+Compare
The use of this setting is highly advised as it prevents data loss due to unstable
flash. Users can set the time gap of power supply between copy and compare.
The time gap can be set from 0 to 15 seconds. The default is "3".
Source Target tolerance setting: ± 1%
Real Capacity 2GB
2.02GB (2GB +1%)
1.98GB (2GB – 1%)
[Power Off Time Between]
3