Manual
25
10. Cleaning and maintenance
a) Cleaning the lter
• Thelterpreventscoarsedirtandmostotherimpurities(e.g.hair,fabricbres,etc.)fromgettingintothepump
drive. Check it regularly, as soiling reduces the pumping capacity.
• Disconnect the pump from the mains voltage by pulling the mains plug out of the mains socket.
• Releasetheexcesspressureinthehosesystemorpump,opentheshut-offvalves(ifany)andcarefullyopenthe
ltercover(turnthecovercounter-clockwisetotheleft).Removethecover.
• Pulloutthelterinsertandcleanitthoroughly.Itisalsorecommendedtocheckthelteropeninginthepumpfor
soiling (drain water from the pump if necessary).
• Insertthelterinthecorrectorientation.Beforerestartingthepump,llthepumpwithcleanwaterthroughthelter
opening. Replace the cover and screw it tight.
Ifthesuctionhoseendhasacoarselter/backowpreventer,checkitaswellorcleanit.
b) General information
Apartfromltercleaning(seesection10.a),thepumphasnouserserviceableparts,soneveropenordismantleit.
Maintenance, repair and associated pump dismantling may only be carried out by a specialist or a specialist workshop.
Before cleaning the pump, disconnect it from the mains voltage by pulling the mains plug out of the mains socket.
Allow the pump to cool down completely.
Use a dry, clean, soft and lint-free cloth to clean the outside of the pump.
Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may damage the
housing or prevent the product from functioning properly.
11. Disposal
Electronic devices are recyclable waste and must not be placed in household waste. At the end of its
service life, dispose of the product according to the relevant statutory regulations.