Flip inverter power to the “OFF’ position
Unscrew the screw terminals along the edge of the side plate
Gently remove DC Side plate to expose DC Terminals
Connect the positive and negative DC Cables to their respective terminals and run them
through the side panel
The Terminals must clean to reduce the resistance in the cable connection. A
buildup of dirt or oxidation may eventually lead to the cable terminal overheating
during periods of high current draw
DC WIRING
The Renogy Pure Sine Wave Inverters are suitable for 12V battery bank systems ONLY.
Not following the minimum DC requirement will cause irreversible damage to the unit.
WARNING
WARNING
CAUTION
Be careful of the positive and negative poles. Reversing the poles might cause
permanent damage to the inverter. It will surely blow the internal fuse.
NOTE
Damage to the Renogy inverters due to reverse polarity is NOT covered by warranty.
NOTE
NOTE
The input terminals of the inverters have large capacitors connected to them. Once
a positive and negative wire are connected to the terminals, it will complete the
circuit, and commence drawing a heavy current momentarily. As a result, there may
be a sparking occurring even if the inverter is in the off position. To minimize
sparking, it is recommended that the user have the appropriate size wire feeding into
the inverters and/or install an external fuse leading into the inverter.
Ensure all sources of DC power (i.e., batteries, solar, etc.) and AC power (utility
power or AC generator) are de-energized (i.e., breakers opened, fuses removed)
before proceeding—to prevent accidental shock.