FAN Operation
Main Menu
By default, when first powering the unit the fans and alarm will run for approximately
1 minute as part of the start-up routine. Other fan ON/OFF operation parameters are
listed below:
Condition
Inverter Mode Load Percentage
DC Input Current
Inverter Heat Sink Temperature
Turn on Condition
Current ≥ 10A
Uptime ≤ 1 minute
Load ≥ 35%
Temperature ≥50
Turn off Condition
Current < 6A
Uptime > 1 minute
Load < 35%
Temperature < 45
Inverter Charger Uptime
Exit setting mode, go back to main menu
1. Hold down to enter Parameter setting menu.
Cycle through the menu
Cycle through the menu
2. Tap to change/confirm setting in parameter setting menu
Function Keys
Upon successful connection of a 12V deep cycle battery bank, flip the inverter power to the ON
position.
Use the up and down arrows to cycle through the menu. The following is what is displayed:
NOTE
NOTE
Upon successful connection of a 12V deep cycle battery bank, flip the inverter power
to the ON position.
NOTE
The unit may also be powered on by the wired remote control.
Operation