Full Product Manual

14
Inverter Troubleshooting
Eco Power Saving Mode Instruction
This inverter features a power saving mode to conserve battery power. To enable this
function, set the DIP switch to ECO.Please note, the DIP Switch for the mode needs to be
set BEFORE turning on the inverter.
Under power saving mode the inverter senses the output power being drawn. It shuts down
the output power and remains on standby with lower idle consumption if the AC load is less
than 50 watts.
The inverter will send a pulse once every 3 seconds to look for AC load. You will also notice
the power light start to pulse, indicating ECO mode. If the inverter detects a load greater than
50 watts it will automatically start inverting, restores the output to power the load. When all
loads are turned off the inverter will go back into search mode.
Input voltage is below 11V
Input voltage is above 15V
Input voltage is below 10.5V
Input voltage is above 15.5V
GFCI tripped
Use a higher wattage inverter or
use a lower powered device
Disconnect the inverter and turn
off the ON/OFF switch to reset
Disconnect appliances and turn
off the ON/OFF switch to reset
Inverter overheats
Operating equipment draws too
much power
Yellow LED Lit -
Inverter shut down
Fault LED Lit, Inverter
Shut Down and alarm on
Fault LED Lit and
alarm beeps
Inverter is short circuited
Keep input voltage below 15V
Keep input voltage above 10.5V
Keep input voltage below 15.5V
Allow inverter to cool down
Check for adequate ventilation
Reduce the load on inverter
Keep input voltage above 11V
Indicator TroubleshootPotential Issue