Full Product Manual
07
Alarm
—If there is a buzzing sound, the battery is low. The user should reduce the
AC load, charge the battery, and check the DC cable for excessive losses.
LEFT
Neutral (N) Ground(G)
Middle Right
Live(L)
2. Power LED (Green)
— When this green LED is lit, the inverter is operating.
— When this green LED is flashing, the inverter is in ECO power
saving mode.
3.
Facing the front panel, the terminals are:
NOTE
4.
5.
6.
7.
8.
9.
NEUTRAL and GROUND are bonded inside the inverter to comply with the National Electric
Code (NEC) requirement that any AC source must have aneutral to ground connection.
GFCI LED (Yellow)
— When the yellow LED is lit, the ground fault circuit has been interrupted.
Shut down the inverter and restart.
Fault LED (Red)
— The red indicator turns on as the inverter shuts down due to overheating,
overload,
under voltage, or over voltage.
Immediately turn off all AC appliances if the Fault LED is lit. Allow the inverter to cool
before continuing. Make sure that the ventilation vents are not blocked.
If an inverter shutdown was preceded by a buzzing sound, there may be an excessive
load in combination with low voltage or a cable problem.
ON/OFF Switch
— Controls AC Output and Remote feature
AC Outlets
— Up to 8.3 amps (1000W), Up to 15 amps (2000W) at 110V AC 60 Hz.
Communication Port
—RS485,data transmission
Remote Switch Connection
— Insert wired remote switch to the connection port. Set
ON/OFF switch to "remote" position.
50Hz/60Hz-
Switches between 50Hz and 60Hz
Eco/Nor-
Switches between Energy Saving mode and Normal mode