Portable LFP Battery Charger Quick Guide SKU: RBC10A2P
Important Safety Instructions WARNING Indicates a potentially dangerous condition. Use extreme caution when performing this task. CAUTION Indicates a critical procedure for the safe and proper installation and operation of the battery. NOTE Indicates a procedure or function that is important to the safe and proper operation of the battery. Disclaimer The manufacturer accepts no liability for any damage caused by: Force majeure including fire, typhoon, flood, earthquake, war, and terrorism.
Any uncovered battery material, such as electrolyte or powder, that has contacted skin or the eyes must be flushed out with plenty of clean water immediately. Seek medical attention afterwards. Spills on clothing should be rinsed out with water. DO NOT touch the exposed electrolyte or powder if the battery casing is damaged. Please make sure any battery charger(s) or charge controller(s) are disconnected when working on the battery.
General Information Renogy 10A AC to DC Charger (RBC10A2P) is an automatic and portable charger intended for 24V LFP batteries. This charger includes 14AWG alligator clips and outputs power based on the power, voltage, and current condition of the battery. The charger has an LED status indicator for providing a visual means to determine the operating mode and condition of the battery connected to the charger. The AC-DC portable charger will automatically monitor and maintain the battery at full charge.
Dimensions 4.25in / 108mm 2.52in / 64mm 9.17in / 233mm 5.91in / 150mm XT90H 23.
23.32in / 600mm 14AWG 15A 5.12in / 130mm 23.32in / 600mm 14AWG 15A 5.12in / 130mm 0.33in / 8.4mm Operation There are two ways to make the charger work normally. Alligator Clips 15A 1. The black alligator clip represents the negative pole, and the red clip represents the positive pole. 2. Connect the negative alligator clip to the negative terminal on the LFP battery, and then do the same for the positive terminal.
Ring Terminal 15A 1. The black ring terminal represents the negative pole, and the red ring terminal represents the positive pole. 2. Connect the negative ring terminal to the negative terminal on the LFP battery, and then do the same for the positive terminal. LED Status LED Status Description Solid Red Indicates that the 24V LFP battery is being charged with a charging current range between 1A and 10A. Green There are two statuses: 1. The charger is not connected to the battery. 2.
Troubleshooting Condition Short Circuit Protection Over-temperature Protection Undervoltage Protection Steps to Take 1. When there is a short circuit between the two poles of the ring terminals in the battery charger, the Short Circuit Protection will be triggered. The charger stops working immediately, and the LED indicator goes out. 2. Disconnect the connecting wire of the AC terminal immediately.
Condition Overvoltage Protection Steps to Take 1. When the voltage at the output terminal of the charger is greater than 32V, the Overvoltage Protection will be triggered. At this time, the indicator light will go out and the charger will stop working. 2. Disconnect the battery immediately and check the charger. Reverse Connection Protection 1. When the charger triggers the Reverse Connection Protection, the external fuse on the connection line will blow, the charger will not work normally. 2.
Technical Specifications Model RBC10A2P Input Voltage 100V to 240V AC, 50 Hz/60 Hz Input Amps 5A Max Output Voltage 28.8 (±0.2)V DC Output Amps Minimum Battery Voltage 10 (±0.5)A 13V to 15V DC Efficiency 110VAC 90% Min 230VAC 92% Min Room Operating Temperature -29℃ to 45.5℃ / -20℉ to 113.9℉ Storage Temperature -40℃ to 75℃ / -40℉ to 167℉ 50mA Max Self-Consumption Current Protection Dimensions 250V 10A Fuse built in Weight Cable Length 3.8 lbs / 1.7 kg approx. 47.2 in / 1200 mm 9.17 x 4.
Charge Curve STATUS LED RED GREEN 28.8V 28V 25V 15V Voltage 10A CC MODE 8A 5A 3A Current CV MODE 10 1A 0.
Manufacturer: RENOGY New Energy Co.,Ltd. Address: No.66, East Ningbo Road Room 624-625 Taicang German Overseas Students Pioneer Park JiangSu 215000 CN Manufacturer: RENOGY New Energy Co.,Ltd. Address: No.66, East Ningbo Road Room 624-625 Taicang German Overseas Students Pioneer Park JiangSu 215000 CN UK REP EVATOST CONSULTING LTD Suite 11, First Floor, Moy Road Business Centre, Taffs Well, Cardiff, Wales, CF15 7QR contact@evatmaster.