Installation Guide

SM
SOLAR
MOUNT
INSTALLATION GUIDE
PAGE
Aluminum mid clamp with stainless steel bonding pins that pierce module frame
anodization to bond module to module through clamp
Stainless steel nut bonds aluminum clamp to stainless steel T-bolt
Serrated T-bolt head penetrates rail anodization to bond T-bolt, nut, clamp, and
modules to SM rail
BONDING MIDCLAMP ASSEMBLY BONDING MIDCLAMP ASSEMBLY BONDING RAIL SPLICE BAR
BONDING MICROINVERTER MOUNT
RAIL TO L-FOOT w/BONDING T-BOLT
RAIL TO L-FOOT
w/BONDING T-BOLT
BONDING RAIL
SPLICE BAR
RACK SYSTEM GROUND
MODULE FRAME
BONDING CONNECTION GROUND PATHS
N
Bonding Hardware creates bond between splice
bar and each rail section
Aluminum splice bar spans across rail gap to
create rail to rail bond. Rail on at least one side
of splice will be grounded.
Note: Splice bar and bolted connection are
non-structural. The splice bar function is rail
alignment and bonding.
Serrated ange nut removes L-foot anodization
to bond L-Foot to stainless steel T-bolt
Serrated T-bolt head penetrates rail anodization
to bond T-bolt, nut, and L-foot to grounded
SM rail
Hex nut with captive lock washer bonds metal
microinverter ange to stainless steel T-bolt
Serrated T-bolt head penetrates rail anodization
to bond T-bolt, nut, and L-foot to grounded
SM rail System ground including racking and
modules may be achieved through the trunk cable
of approved microinverter systems. See page I for
details
WEEB washer dimples pierce anodized rail to
create bond between rail and lug
Solid copper wire connected to lug is routed to
provide nal system ground connection.
NOTE: Ilsco lug can also be used when secured to
the side of the rail. See page J for details
WEEBLUG (OR ILSCO LUG)
SM RAILSM RAIL
SM RAILSM RAIL
SM RAILSM RAIL
SM RAILSM RAIL
MODULE FRAME
BONDING T-BOLT
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
11
3
3
BONDING HARDWARE
SPLICE BAR
SM RAIL
MICRO-INVERTER FLANGE
SERRATED FLANGE NUT
L-FOOT
B
O
N
D
I
N
G
T
-
B
O
L
T
1
SEE NOTESEE NOTE
HEX NUT W/ CAPTIVE
LOCK WASHER
BONDING
T-BOLT
SOLID COPPER WIRE
BONDING
MICROINVERTER
MOUNT
BONDING MIDCLAMP
ASSEMBLY
RACK SYSTEM
GROUND
Note: Note:
Only one lug per module row requiredOnly one lug per module row required
3
A B
C
D
E
B
A
C
D
E
Option 1:
Ground Through
Enphase Trunk Cable
Option 2: Ground Lug w/
Bare Copper Wire