Installation Guide

SM
SOLAR
MOUNT
INSTALLATION GUIDE
PAGE
P
TRIM AND END CAP INSTALLATION
TRIM MIDCLAMPS: Ensure Trim lip is in contact with
module face and verify alignment marks on T-bolts
are in proper position, tighten midclamp on Trim,
repeat at each gap between modules.
TORQUE VALUE (See table and notes on PG. A)
11 ft-lbs. No anti-seize.
INSTALL END CAPS: End caps install as supplied on
SM standard rail and SM light rail. If desired for SM
light rail, the end cap may be modied as shown by
hand, or by using a cutting tool.
Break line and
discard top piece
for SM Light Rail
FINISH TRIM INSTALLATION. CUT EXCESS TRIM AND
INSTALL TRIM CLIPS:
Attach trim to modules with at least one trim clip at
each end of array and at locations where additional
support is needed. Each section of trim must be
attached to modules with at least one mid clamp.