Installation Guide
SM
SOLAR
MOUNT
INSTALLATION GUIDE
PAGE
Stainless steel Midclamp points, 2 per module,
pierce module frame anodization to bond
module to module through clamp.
Serrated ange nut bonds stainless steel clamp
to stainless steel T-bolt
Serrated T-bolt head penetrates rail anodization
to bond T-bolt, nut, clamp, and modules to
grounded SM rail.
BONDING MIDCLAMP ASSEMBLY ENDCLAMP ASSEMBLY
BONDING MICROINVERTER MOUNT
RAIL TO L-FOOT
w/BONDING T-BOLT
BONDING RAIL
SPLICE BAR
RACK SYSTEM GROUND
Serrated ange nut bonds aluminum Endclamp
to stainless steel T-bolt
Serrated T-bolt head penetrates rail anodization
to bond T-bolt, nut, and Endclamp to grounded
SM rail
Note: End clamp does not bond to module frame.
MODULE FRAME
MODULE FRAME
BONDING CONNECTION GROUND PATHS
X
Hex nut with captive lock washer bonds metal
microinverter ange to stainless steel T-bolt
Serrated T-bolt head penetrates rail anodization
to bond T-bolt, nut, and L-foot to grounded
SM rail System ground including racking and
modules may be achieved through the trunk cable
of approved microinverter systems. See page I for
details
WEEB washer dimples pierce anodized rail to
create bond between rail and lug
Solid copper wire connected to lug is routed to
provide nal system ground connection.
NOTE: Ilsco lug can also be used when secured to
the side of the rail. See page J for details
WEEBLUG (OR ILSCO LUG)
SM RAILSM RAIL
SM RAILSM RAIL
SM RAILSM RAIL
SM RAILSM RAIL
MODULE FRAME
BONDING T-BOLT
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
11
3
3
BONDING T-BOLT
SERRATED
NUT
SPLICE BAR
SM RAIL
MICRO-INVERTER FLANGE
SEE NOTESEE NOTE
HEX NUT W/ CAPTIVE
LOCK WASHER
BONDING
T-BOLT
SOLID COPPER WIRE
BONDING MICROINVERTER
MOUNT
ENDCLAMP ASSEMBLY
BONDING MIDCLAMP
ASSEMBLY
RACK SYSTEM GROUND
Note: Only one lug per module row
required
BONDING HARDWARE
A C
B
D
E
F
A
B
D
C
EF
Ground Lug w/ Bare Copper WireGround Lug w/ Bare Copper Wire
BONDING RAIL SPLICE BAR
Bonding Hardware creates bond between splice
bar and each rail section
Aluminum splice bar spans across rail gap to
create rail to rail bond. Rail on at least one side
of splice will be grounded.
Note: Splice bar and bolted connection are
non-structural. The splice bar function is rail
alignment and bonding.
2
1
RAIL TO L-FOOT w/BONDING T-BOLT
Serrated ange nut removes L-foot anodization
to bond L-Foot to stainless steel T-bolt
Serrated T-bolt head penetrates rail anodization
to bond T-bolt, nut, and L-foot to grounded
SM rail
SM RAILSM RAIL
2
2
1
SERRATED FLANGE NUT
L-FOOT
B
O
N
D
I
N
G
T
-
B
O
L
T
1