System Certification
PAGE
APPENDIX A
A
The SOLARMOUNT system has been certied and listed to the UL 2703 standard (Rack Mounting Systems and Clamping Devices for Flat-Plate Photovoltaic
Modules and Panels). This standard included electrical grounding, electrical bonding, mechanical load and re resistance testing.
In conducting these tests, specic modules are selected for their physical properties so that the certications can be broadly applied. The following lists the
specic modules that were tested and the applicability of those certications to other modules that might come onto the market.
In addition to UL 2703 certication, Unirac performs internal testing beyond the requirements of certication tests in order to establish system functional
limits, allowable loads, and factors of safety. These tests include functional system tests, and destructive load testing.
Mechanical Load Test Modules System Level Fire Classication
The modules selected for UL 2703 mechanical load testing were
selected to represent the broadest range possible for modules on
the market. The tests performed cover the following basic module
parameters:
The system re class rating requires installation in the manner
specied in the SOLARMOUNT Installation Guide. SOLARMOUNT
has been classied to the system level re portion of UL 1703.
This UL 1703 classication has been incorporated into our UL
2703 product certication. Class A system level re performance is
inherent in the SOLARMOUNT design, and no additional mitigation
measures are required. The re classication rating is only valid
on roof pitches greater than 2:12 (slopes ≥ 2 inches per foot, or
9.5 degrees). There is no required minimum or maximum height
limitation above the roof deck to maintain the system re rating
for SOLARMOUNT. Module Types & System Level Fire Ratings are
listed below:
• Frame thicknesses greater than or equal to 1.0 mm
• Basic single and double wall frame proles (some
complex frame proles could require further analysis to
determine applicability)
• Clear and dark anodized aluminum frames
• UL2703 Certication Load Ratings:
o Down– 113.4 PSF , Up – 50.4 PSF , Down-Slope – 14.7 PSF
• Tested Loads:
o Down – 170.10 PSF , Up – 75.60 PSF, Down-Slope – 22.05 PSF
• Maximum Area of Module = 21.06 sqft
Module Manufacturer Model/Series
Hyundai HiS-S325TI
Rail Type Module Type
System
Level
Fire Rating
Rail
Direction
Module
Orientation
Mitigation
Required
Standard
Rail
Type 1, Type 2,
Type 3, & Type 10
Class A, B, & C
East-West
North-South
Landscape
OR
Portrait
None
Required
Light Rail Type 1 & Type 2 Class A, B, & C
East-West
North-South
Landscape
OR
Portrait
None
Required
Tested Modules