Full Product Manual

9
Electrical characteristics are displayed below:
Module
Rated
Power
(W)
Voltage
at Rated
Power,
Vmpp
(V)
Current
at Rated
Power,
Impp (A)
Open
Circuit
Voltage
(V)
Maximum
System
Voltage
UL Vmax
(V)
RNG260D
260
30.40
8.56
37.60
1000
RNG250D
250
30.10
8.32
37.50
1000
RNG150D
150
17.90
8.38
22.5
1000
RNG100D
100
18.9
5.29
22.5
1000
RNG50D
50
18.5
2.70
22.7
1000
RNG30D
30
17.5
1.71
21.6
1000
RNG20D
20
17.5
1.14
21.6
1000
RNG10D
10
17.5
0.57
21.6
1000
RNG300P
300
37.46
8.01
46.12
1000
RNG270P
270
30.80
8.77
37.90
1000
RNG260P
260
30.40
8.56
37.60
1000
RNG250P
250
30.20
8.26
37.30
1000
RNG100P
100
17.8
5.62
22.4
1000
RNG50P
50
17.8
2.84
22.4
1000
Max
Rated
Current
10A
Rated electrical characteristics are within 10% of measured values at STC
Conditions of 1000W/m
2
, 25°C cell temperature, and spectral irradiation of
AM 1.5 spectrum.
5.2 Cables and Wiring
Renogy modules are equipped with two (2) stranded, PV-rated, output
MC4 cables. The positive connector is a male connector and the negative
connector is a female connector. These wires by themselves are rated for
series connections, but could be adapted to hold parallel connections with
an extra component such as a combiner box or an MC4 adaptor for parallel
strings. Renogy recommends that only sunlight resistant cables be used
with the minimum wire size being 4mm
2
in diameter.
Wiring
Type
Ratings
PV Wire
PV1-F1x4.0mm
2
Rated Voltage: 1800VDC
-4°C Up to 120°C
MC4 Connectors
LJQ-1
Rated Voltage:1800VDC
Rated Current: 16A
-40°C Up to 120°C
Junction Box
PV-JM801
Rated Voltage: 1000VDC
Up to 15A
Keep connectors dry and clean and ensure that caps are tightly
sealed before connecting modules
Faulty connections can result in electrical shock so make sure to
fasten all connections securely.
Renogy modules can be installed in landscape or portrait orientation.
Make sure that the proper distance between the panels and the
surface to allow for air circulation.
Portrait Orientation Landscape Orientation
Series Connections are just plug and play with the male and female
MC4 connectors
Parallel connections will utilize MC4 branch connectors for
centralizing all positive and all negative connections.
5.3 Bypass Diodes
The junction boxes used with the Renogy modules contain bypass
diodes that are wired in parallel with the PV string cells. In the event the
modules experience partial shading, the diodes are activated to bypass
the current generated by the non-shaded cells, therefore limiting module
heating and performance losses. However, they do not protect the panel
from over-current. Over-current protections devices must be used when
connecting more than 2 modules in series.
If the bypass diodes are suspected of failure, installers or maintenance
personnel should contact the company (Renogy).
Model
Rating
SPA2040
Tj Max = 200°C, if 20A
In systems with more than two modules in series, high reverse
current can flow through cells that are shaded partially or outright
when part of a module is shaded and the rest is exposed to the sun.