Full Product Manual

16
Programming Load Terminal
1. This screen is displaying the current Load Mode.
2. To enter screen 2 press and hold the Enter button. This screen will allow you to
change the load mode.
3. To change the load mode press the up or down button.
4. Once you have selected the desired load mode press the Enter button to save
the setting.
5. To exit the programming setting press the left button.
Load Mode Options
Setting
Mode
Description
0
Automatic(On/Off)
The load will turn on at night when the solar
panel is no longer producing any power after
a short time delay. The load will turn off when
the panel starts producing power.
1-14
Time control
When the panel is no longer producing power
the load will be ON for 1-14 hours or until the
panel starts producing power.
15
Manual
In this mode, the user can turn the Load
On/Off by pressing the Enter button at any
time.
16
Test
Used to troubleshoot load terminal (No Time
Delay). When voltage is detected load will be
off and when no voltage is detected load will
be on.
17
24Hr
The load will be on for 24 hours a day.
1
2
3
4
5