Model Rating
20A
Normal Battery Voltage
12V
Maximum Solar Voltage(OCV)
26V
Maximum Battery Voltage
17V
Rated Charging Current
20A
Battery Start Charging Voltage
3V
Electrical Protection and Feature
Grounding
EMC Conformity
Self-consumption
Maintenance
Fusing
Technical Specifications
For best controller performance, it is recommended that these tasks be performed from time to time.
1. Check wiring going into the charge controller and make sure there is no wire damage or wear.
2. Tighten all terminals and inspect any loose, broken, or burnt up connections
3. Occasionally clean the case using a damp cloth
Fusing is a recommendation in PV systems to provide a safety measure for connections
going from panel to controller and controller to battery. Remember to always use the
recommended wire gauge size based on the PV system and the controller.
AWG 16 14 12 10 8 6 4 2
0
Max.
Current
55A30A20A15A10A
75A
95A
130A 170A
NEC Maximum Current for different Copper Wire Sizes
< 8mA
FCC Part-15 class B compliant; EN55022:2010
Common Negative
Transient overvoltage protection, at the solar input
and battery output protects against surge voltage
Over temperature protection with derating
charging current
Reverse current from battery to solar panel
protection at night
Reverse polarity solar and battery connection
Spark-free protection.
Electrical Parameters